Nexans AIN Indoor MV Slip-On Cold Shrink Terminations (Single Core | 42kV) - AIN 10, AIN 20, AIN 30, AIN 36

Product overview

Nexans AIN Indoor MV Slip-On Cold Shrink Terminations (Single Core | 42kV)

Nexans AIN Indoor MV Slip-On Cold Shrink Terminations (Single Core | 42kV) are reliable, high-performance indoor terminations for polymeric insulated MV cables with extruded or bonded conductive screens. These Nexans AIN Terminations deliver long-term electrical performance in controlled indoor environments. The range includes AIN 10, AIN 20, AIN 30 and AIN 36, covering voltages up to 42kV. Slip-on silicone housings make installation fast and easy without heat or special tools, and a few sizes cover most cable cross-sections. Compatible with three-core, copper wire screened or copper tape screened and armoured cables, this AIN Single Core system is a versatile, dependable indoor solution.
Part Numbers: AIN 10, AIN 20, AIN 30, AIN 36.

Nexans AIN – Kit Contents

  • x3 termination housings
  • x3 mechanical or compression cable lugs for the conductor
  • x3 mechanical or compression screen wire cable lugs
  • Installation instructions
  • Silicone grease
  • Assembly incidentals

AIN Indoor MV Terminations – Features

  • Voltage class: Up to 42kV
  • Application: Indoor use on polymeric insulated MV cables
  • Type: Slip-On Cold Shrink Termination
  • Material: High-quality silicone rubber
  • Standards: CENELEC HD 629.1
  • Quick installation without heat or special tools
  • Suitable for three-core, copper wire screened or copper tape screened and armoured cables

Order Information

Below, you can easily select the Nexans AIN Indoor MV Slip-On Cold Shrink Terminations for each cable voltage:

MAX VOLTAGE 6-10 kV

Part No Section Core Length
3 x AIN 10 Gr. 1 25÷95 mm2 150 mm
3 x AIN 10 Gr. 2 120÷240 mm2 150 mm
3 x AIN 10 Gr. 3 300÷500 mm2 150 mm
3 x AIN 20 Gr. 4 630÷800 mm2 225 mm
3 x AIN 36 Gr. 5 1000 mm2 405 mm
3 x AIN 36 Gr. 6 1200 mm2 405 mm

iMAX VOLTAGE 12-20 kV

Part No Section Core Length
3 x AIN 20 Gr. 1 35÷70 mm2 225 mm
3 x AIN 20 Gr. 2 95÷240 mm2 225 mm
3 x AIN 20 Gr. 3 300÷500 mm2 225 mm
3 x AIN 20 Gr. 4 400÷630 mm2 225 mm
3 x AIN 36 Gr. 5 630÷800 mm2 405 mm
3 x AIN 36 Gr. 6 1000÷1200 mm2 405 mm

MAX VOLTAGE 18-30 kV

Part No Section Core Length
3 x AIN 30 Gr. 1 50÷70 mm2 300 mm
3 x AIN 30 Gr. 2 95÷240 mm2 300 mm
3 x AIN 30 Gr. 3 240÷400 mm2 300 mm
3 x AIN 36 Gr. 5 400÷630 mm2 405 mm
3 x AIN 36 Gr. 6 630÷1200 mm2 405 mm

MAX VOLTAGE 20.8-36 kV

Part No Section Core Length
On Request 50÷70 mm2 On Request
On Request 95÷120 mm2 On Request
3 x AIN 36 Gr. 4 150÷300 mm2 405 mm
3 x AIN 36 Gr. 5 400÷630 mm2 405 mm
3 x AIN 36 Gr. 6 630÷1200 mm2 405 mm

For Additional Information on Nexans AIN Indoor MV Slip-On Cold Shrink Terminations (Single Core | 42kV), please consult the Technical Data Table or PDF Files below.

*Technical Data subject to change without notice.

FREE Technical Advisory Service
E-Tech Components UK Ltd maintains a free technical advisory service.
Contact us for enquiries concerning this and all other products: +44 (0) 1744 762 929

Technical Data

Ordering Part Number Nominal Voltage Uo / U (kV)
Conductor Cross-Section (mm2) - Min. Conductor Cross-Section (mm2) - Max. Dia. over Core Insulation (mm) - Min. Dia. over Core Insulation (mm) - Max. Number
of Sheds
L (mm) Dia. D (mm)
3 x AIN 10 Gr. 1 6/10 25 95 13.0 20.8 2 150 37
3 x AIN 10 Gr. 2 6/10 120 240 19.4 28.4 2 150 43
3 x AIN 10 Gr. 3 6/10 300 500 27.7 36.4 2 150 60
3 x AIN 20 Gr. 4 6/10 630 800 34.0 45.0 3 225 68
3 x AIN 36 Gr. 5 6/10 1000 1000 39.0 50.0 7 405 98
3 x AIN 36 Gr. 6 6/10 1200 1200 46.0 58.0 7 405 98
3 x AIN 20 Gr. 1 12/20 35 70 18.3 23.5 3 225 47
3 x AIN 20 Gr. 2 12/20 95 240 22.5 33.0 3 225 56
3 x AIN 20 Gr. 3 12/20 300 500 31.0 41.0 3 225 68
3 x AIN 20 Gr. 4 12/20 400 630 34.0 45.0 3 225 68
3 x AIN 36 Gr. 5 12/20 630 800 39.0 50.0 7 405 98
3 x AIN 36 Gr. 6 12/20 1000 1200 46.0 58.0 7 405 98
3 x AIN 30 Gr. 1 18/30 50 70 23.8 28.4 6 300 74
3 x AIN 30 Gr. 2 18/30 95 240 27.1 37.6 6 300 74
3 x AIN 30 Gr. 3 18/30 240 400 31.5 42.8 6 300 81
3 x AIN 36 Gr. 5 18/30 400 630 39.0 50.0 7 405 98
3 x AIN 36 Gr. 6 18/30 630 1200 46.0 58.0 7 405 98
On Request 20.8/362 50 70 23.8 28.4 On Request On Request On Request
On Request 20.8/362 95 120 27.1 32.0 On Request On Request On Request
3 x AIN 36 Gr. 4 20.8/362 150 300 31.5 41.0 7 405 98
3 x AIN 36 Gr. 5 20.8/362 400 630 39.0 50.0 7 405 98
3 x AIN 36 Gr. 6 20.8/362 630 1200 46.0 58.0 7 405 98

 

Notes:

The classification does only apply for polymeric insulated XLPE cables (dimensions acc. to DIN VDE 0276-620) with extruded conductive screen. Please contact our sales representative, when using other cable types.

2 Since the dimensions for cables at voltage level 20.8/36 (42) kV are not yet standardised, the conductor cross sections and their assignment of diameters over core insulation given in the table are to be considered as approximate values.

When ordering accessories, we would like to ask you to indicate the checked diameters over core insulation.

Technical Information

  • 1. Longitudinally sealed mechanical or compression cable lug
  • 2. Silicone tube or cap as additional sealing at the transition of cable lug to the termination housing when using mechanical cable lugs
  • 3. High flexibility silicone rubber housing, ensuring a perfect fit to the cable even during load changes
  • 4. Integrated conductive rubber insert
  • 5. Earth cable lug
  • 6. Heat-shrinkable tube
  • 7. Heat-shrinkable break-out
Nexans AIN Indoor MV Slip-On Cold Shrink Terminations (Single Core | 42kV) - Technical Image

Find out more about our products or becoming a supplier