CCG IPlus Corrosion Guard Captive Component Industrial Cable Gland

Product overview

CCG IPlus Corrosion Guard Captive Component Cable Gland

CCG IPlus Corrosion Guard Captive Component Cable Gland is a Corrosion Resistant Industrial Cable Gland Device for Steel Wire Armoured (SWA) Cable. Designed for Highly Corrosive Areas.

CCG IPlus Corrosion Guard Part Numbers: 054600-16-IP, 054600-IP, 0546-0-IP, 054601-IP, 054602-IP, 054603-IP, 054604-IP, 054605-IP, 054606-IP, 054607-IP, 054608-IP, 054609-IP, 054610-IP

Features & Benefits

  • For highly corrosive and wet locations.
  • Factory fitted captive elastomeric seals for Built-in Safety™.
  • The screw-on Corrosion Guard™ is manufactured from non-corrosive material to protect the armour and  metal parts of the gland.
  • The Corrosion Guard™ screws onto the gland body and seals over the outer sheath of the cable giving an IP66/68 and deluge proof seal.
  • Cable Gland is precision manufactured from high-quality brass (nickel-plated).
  • Complete with sealing gasket and with a heavy-duty locknut.

CCG IPlus Technical Data

Type: Iplus Corrosion Guard Industrial Gland
Gland Material: Brass (Nickel Plated) BS 2874, EN 12164
Corrosion Guard Material: Glass Reinforced Polyester Compound / PBT
Sealing Material: Thermoset Elastomer (Standard)
Cable Type: Steel Wire Armour
Armour Clamping: Captive Rotating Cone and Inspectible Cone Ring
Sealing Area: Inner and Outer sheath and total enclosure of the metal gland body
Optional Accessories: Adaptor, Reducer, Locknut and Serrated Washer

Installation Standards

  • AS/NZS 3000
  • BS 6121-5
  • BS 7671
  • BS 7430
  • IEC 60364-5-54
  • SANS 0142

Additional Technical Data of CCG IPlus Corrosion Guard Captive Component Industrial Cable Gland part numbers can be found on the table below. For Standards, Certifications & Fitting Instructions, please advise PDF Files.

FREE Technical Advisory Service
E-Tech Components UK Ltd maintains a free technical advisory service.
Contact us for enquiries concerning this and all other products: +44 (0) 1744 762 929

Technical Data

Product Code Gland Size Ref.  Metric Entry Thread (C) Metric Entry Thread (Min D) Cable Detail (Min A) Cable Detail (Max A) Cable Detail (Min B) Cable Detail (Max B) Max Length (E) Armour Dia
(Min F)
Armour Dia
(Max F)
Max Dia
(G)
Hexagonal Detail
(Max Flats)
Hexagonal Detail
(Max Crns)
Installation Torque Value (Nm)
054600-16-IP 00-16ss M16 x 1.5 10 3.0 8.5 8.0 13.5 50 - 0.90 35 ♥ 24 ♥ 27 35.0
054600-IP 00-20ss M20 x 1.5 10 3.0 8.5 8.0 13.5 50 - 0.90 35 ♥ 24 ♥ 27 35.0
0546-0-IP 0-20s M20 x 1.5 10 7.0 12.0 11.5 16.0 50 0.90 1.25 35 ♥ 24 ♥ 27 35.0
054601-IP 1-20 M20 x 1.5 10 11.5 15.0 14.5 20.5 61 0.90 1.25 36 27 30 35.0
054602-IP 2-25 M25 x 1.5 10 14.0 20.0 20.5 26.5 68 1.25 1.60 46 35 39 50.0
054603-IP 3-32 M32 x 1.5 10 19.0 26.5 26.5 33.5 75 1.60 2.00 53 42 47 70.0
054604-IP 4-40 M40 x 1.5 15 26.0 34.0 33.0 42.5 86 1.60 2.00 68 52 59 90.0
054605-IP 5-50 M50 x 1.5 15 34.0 44.5 42.5 52.5 102 2.00 2.50 84 65 73 100.0
054606-IP 6-63 M63 x 1.5 15 44.0 56.5 52.5 65.5 122 2.00 2.50 110 80 90 120.0
054607-IP 7-75 M75 x 1.5 15 56.0 67.5 65.5 78.0 135 2.00 3.15 124 96 108 120.0
054608-IP 8-80 M80 x 2.0 20 68.0 74.0 78.0 82.0 160 2.50 3.15 124 96 108 120.0
054609-IP 9-90 M90 x 2.0 20 74.0 81.5.0 82.0 91.0 170 3.00 3.50 140 111 125 120.0
054610-IP 10-100 M100 x 2.0 20 81.0 91.0 90.0 100.0 180 3.00 3.50 140 125 141 120.0

All dimensions are in mm.

♥ : When manufactured in Aluminium, Hex will be 27 Across Flats and 30 Across Corners.

CCG IPlus Corrosion Guard Captive Component Gland Diagram

 

Find out more about our products or becoming a supplier