Elpress Un-Insulated Insulation Boots
Product overview
Elpress Un-Insulated Insulation Boots
Elpress Un-Insulated Insulation Boots are used together with straight and angled receptacle/ tab connections.
Part Numbers: Elpress ISO1003FL1, ISO1005FL1, ISO1507H-BW6, ISO1507FLS, ISO2507FLS1, ISO1507FLB.
General Information
SYSTEM ELPRESS
System Elpress consists of Terminals and Tools designed and tested together to give a certified crimping result. This ensures that users will feel confident when using our systems, and the achievement of a secure connection through the proper handling of our products. By using Elpress Cu-Connection elements together with one of Elpress Crimp Systems one obtains a connection tested according to the requirements of IEC 61238:1.
UN-INSULATED TERMINALS
Elpress Through Connectors, Ring, Pipe, Fork and Pin terminals produced from high quality Copper 99.95%. The Receptacles and Sockets made of brass. All terminals then get electro-tin plating for maximum corrosion protection. Terminals made of copper bands have a brazed soldered neck, which means that user can crimp them in any direction.
Marking & Approvals
LABELLING
Elpress uninsulated terminals have a clear marking with logotype, area and any screw diameter to facilitate work and checkability.
UL-APPROVED TERMINALS
KR/ KS, KRF/ KRS, KRFS, KRT/ KST UL-approved in accordance with file no E205350. UL-certified products delivered with UL marking on the label including the UL file number and/ or certification code for control by an UL inspector. You can download the certificate at UL Product IQ.
For more information on Elpress Un-Insulated Insulation Boots (ISO1003FL1, ISO1005FL1, ISO1507H-BW6, ISO1507FLS, ISO2507FLS1, ISO1507FLB), see PDF File below.
*Technical Data subject to change without notice.
FREE Technical Advisory Service
E-Tech Components UK Ltd maintains a free technical advisory service.
Contact us for enquiries concerning this and all other products: +44 (0) 1744 762 929
Interested in this Product?
+44 (0)1744 762 929Technical Data
- Used together with straight and angled receptacle / tab connections.
Figure | Cat. No. | L (mm) | W (mm) | Insulation Material |
For Tab | Max Ø Conductor | Pcs/Pack | Temp °C Min | Temp °C Max |
1 | ISO1003FL1 | 19 | 5,5 | PE | 2,8 | 2,5 | 100 | -50 | 85 |
2 | ISO1005FL1 | 21 | 7,6 | PVC | 4,8 | 3,2 | 100 | -25 | 75 |
3 | ISO1507H-BW6 | 23 | 11 | PVC | 6,3 | 3,6 | 100 | -25 | 75 |
4 | ISO1507FLS | 24,4 | 9,0 | PP | 6,3 | 3,2 | 100 | -25 | 90 |
5 | ISO2507FLS1 | 22,5 | 9,5 | PE | 6,3 | 3 | 100 | -50 | 85 |
6 | ISO1507FLB* | 17,3 | 15 | PVC | 6,3 | 2,5 | 100 | -25 | 75 |
*Used with 90° receptacle