Sunsynk SunC1 Acure Single-Phase Hybrid Inverters (3.6kW | 5kW | 6kW) - SunC1-3.6LV01(W/B), SunC1-5.0LV01(W/B), SunC1-6.0LV01(W/B)

Product overview

Sunsynk SunC1 Acure Single-Phase Hybrid Inverters (3.6kW | 5kW | 6kW)

The Sunsynk SunC1 Acure Hybrid Inverter (3.6kW | 5kW | 6kW) is a compact, multifunctional energy solution that integrates an inverter, solar charger and battery charger into a single unit. Designed for residential and small commercial solar energy systems, the Sunsynk SunC1 ensures seamless energy management, providing uninterrupted power supply while optimising solar energy use and reducing grid dependence. Available in 3.6kW, 5kW and 6kW models, this versatile SunC1 Acure Hybrid Inverter delivers efficiency, reliability and user-friendly control for modern energy-conscious homes and businesses.

Part Number Max. DC Input Power Max. Output Power
SunC1-3.6LV01(W/B) 3600W 7200W
SunC1-5.0LV01(W/B) 5000W 10000W
SunC1-6.0LV01(W/B) 6000W 12000W

Key Features & Benefits

  • Sunsynk Acure Hybrid InvertersColourful touch LCD display for real-time system monitoring and intuitive visual power flow. Remote monitoring via Wi-Fi, Bluetooth and LAN allows energy tracking from anywhere.
  • New user interface with built-in arc fault detection for enhanced accessibility and safety
  • Programmable smart switches, multi-stage MPPT charging, and configurable battery/grid priority ensure efficient energy use
  • Works with solar panels, grid power, generators, wind turbines, electric vehicles and hot water tank control. Supports on-grid, off-grid, and UPS modes.
  • Built-in protections against overload, over-temperature, short-circuit, and solar panel theft. Smart battery charging protects battery health and extends lifespan.
  • LoRa-enabled for up to 10 Sunsynk Smartlynk devices and 2 CT coils for scalable system control. Parallel connection capability up to 16 units for larger installations.
  • Max charging/discharging currents: 90A (3.6kW), 120A (5kW), 135A (6kW). Supports 6 configurable time periods for optimised battery cycling.
  • Ideal for homes, offices, factories, remote/off-grid locations, construction sites, marine vessels, military locations, and telecom backup power
  • Two colour options available (black or white)

Why Choose Sunsynk SunC1 Acure Hybrid Inverters?

The SunC1 Hybrid Inverter is designed to revolutionise energy management. Its all-in-one design and intelligent features allow you to store surplus solar energy, reduce electricity costs, and maintain continuous power even during grid outages. Whether for home, industrial, or off-grid applications, the Sunsynk Inverter SunC1 combines flexibility, safety, and high performance in a compact, easy-to-install unit.


For Additional Information on Sunsynk SunC1 Acure Single-Phase Hybrid Inverters (3.6kW | 5kW | 6kW), please consult the Technical Data Table or PDF File below.

*Technical Data subject to change without notice.

FREE Technical Advisory Service
E-Tech Components UK Ltd maintains a free technical advisory service.
Contact us for enquiries concerning this and all other products: +44 (0) 1744 762 929

Technical Data

BATTERY INPUT DATA

  SunC1-3.6LV01(W/B) SunC1-5.0LV01(W/B) SunC1-6.0LV01(W/B)
BATTERY TYPE Lead-acid or Lithium-ion Lead-acid or Lithium-ion Lead-acid or Lithium-ion
BATTERY VOLTAGE RANGE 40-60V 40-60V 40-60V
MAX CHARGING CURRENT 90A 120A 135A
MAX DISCHARGING CURRENT 90A 120A 135A
CHARGING STRATEGY FOR LI-ION BATTERY Self-adaption to BMS Self-adaption to BMS Self-adaption to BMS
NUMBER OF BATTERY INPUT 1 1 1

PV STRING INPUT DATA

  SunC1-3.6LV01(W/B) SunC1-5.0LV01(W/B) SunC1-6.0LV01(W/B)
MAX. PV POWER ACCESS 7200W 10000W 12000W
MAX. PV INPUT POWER 5760W 8000W 9600W
MAX. PV INPUT VOLTAGE 500V 500V 500V
START-UP VOLTAGE 125V 125V 125V
MPPT VOLTAGE RANGE 150-425V 150-425V 150-425V
RATED PV INPUT VOLTAGE 370V 370V 370V
MAX. OPERATING PV INPUT CURRENT 18+18A 18+18A 18+18A
MAX. INPUT SHORT-CIRCUIT CURRENT 27+27A 27+27A 27+27A
NO. OF MPP TRACKERS / NO. OF STRINGS MPP TRACKER 2/1+1 2/1+1 2/1+1

AC INPUT / OUTPUT DATA

  SunC1-3.6LV01(W/B) SunC1-5.0LV01(W/B) SunC1-6.0LV01(W/B)
RATED AC INPUT / OUTPUT ACTIVE POWER 3600W 5000W 6000W
MAX. AC INPUT / OUTPUT APPARENT POWER 3960VA 5500VA 6600VA
PEAK POWER (OFF-GRID) 2 times of rated power, 10s 2 times of rated power, 10s 2 times of rated power, 10s
RATED AC INPUT / OUTPUT CURRENT 16.4/15.7A 22.8/21.8A 27.3/26.1A
MAX. AC INPUT / OUTPUT CURRENT 18/17.3A 25/24A 30/28.7A
MAX. CONTINUOUS AC PASSTHROUGH (GRID TO LOAD) 35A 35A 40A
MAX. OUTPUT FAULT CURRENT 36A 50A 60A
MAX. OUTPUT OVERCURRENT PROTECTION 70A 80A 80A
RATED INPUT / OUTPUT VOLTAGE / RANGE 220/230V 0.85Un-1.1Un 220/230V 0.85Un-1.1Un 220/230V 0.85Un-1.1Un
RATED INPUT / OUTPUT GRID FREQUENCY / RANGE 50Hz/45-55Hz, 60Hz/55-65Hz 50Hz/45-55Hz, 60Hz/55-65Hz 50Hz/45-55Hz, 60Hz/55-65Hz
GRID CONNECTION FORM L+N+PE L+N+PE L+N+PE
POWER FACTOR ADJUSTMENT RANGE 0.8 leading to 0.8 lagging 0.8 leading to 0.8 lagging 0.8 leading to 0.8 lagging
TOTAL CURRENT HARMONIC DISTORTION THDI <3% (of nominal power) <3% (of nominal power) <3% (of nominal power)
DC INJECTION CURRENT <0.5% In <0.5% In <0.5% In

EFFICIENCY

  SunC1-3.6LV01(W/B) SunC1-5.0LV01(W/B) SunC1-6.0LV01(W/B)
MAX. EFFICIENCY 97.6% 97.6% 97.6%
EURO EFFICIENCY 96.5% 96.5% 96.5%
MPPT EFFICIENCY >99% >99% >99%

PROTECTION

  SunC1-3.6LV01(W/B) SunC1-5.0LV01(W/B) SunC1-6.0LV01(W/B)
INTEGRATED DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Overvoltage Load Drop Protection, Ground Fault Current Monitoring, Arc Fautl Circuit Interrupter (optional), Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch, DC Termina lInsulation Impedance Monitoring, Residual Current (RCD) Detection, Surge protection level DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Overvoltage Load Drop Protection, Ground Fault Current Monitoring, Arc Fautl Circuit Interrupter (optional), Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch, DC Termina lInsulation Impedance Monitoring, Residual Current (RCD) Detection, Surge protection level DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Overvoltage Load Drop Protection, Ground Fault Current Monitoring, Arc Fautl Circuit Interrupter (optional), Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch, DC Termina lInsulation Impedance Monitoring, Residual Current (RCD) Detection, Surge protection level
SURGE PROTECTION LEVEL TYPE II(DC), TYPE II(AC) TYPE II(DC), TYPE II(AC) TYPE II(DC), TYPE II(AC)

INTERFACE

  SunC1-3.6LV01(W/B) SunC1-5.0LV01(W/B) SunC1-6.0LV01(W/B)
DISPLAY LCD+LED LCD+LED LCD+LED
COMMUNICATION INTERFACE RS485/RS232/CAN RS485/RS232/CAN RS485/RS232/CAN
MONITOR MODE GPRS/WIFI/Bluetooth/4G/LAN (optional) GPRS/WIFI/Bluetooth/4G/LAN (optional) GPRS/WIFI/Bluetooth/4G/LAN (optional)

GENERAL DATA

  SunC1-3.6LV01(W/B) SunC1-5.0LV01(W/B) SunC1-6.0LV01(W/B)
OPERATING TEMPERATURE RANGE -40 to +60°C, >45°C Derating -40 to +60°C, >45°C Derating -40 to +60°C, >45°C Derating
PERMISSABLE AMBIENT HUMIDITY 0-100% 0-100% 0-100%
PERMISSABLE ALTITUDE 2000m 2000m 2000m
NOISE <30dB <30dB <30dB
INGRESS PROTECTION (IP) RATING IP65 IP65 IP65
INVERTER TOPOLOGY Non-Isolated Non-Isolated Non-Isolated
OVER VOLTAGE CATEGORY OVC II(DC), OVC III(AC) OVC II(DC), OVC III(AC) OVC II(DC), OVC III(AC)
CABINET SIZE (W x H x D) 376 x 530 x 276.22mm (Excluding Connectors and Brackets) 376 x 530 x 276.22mm (Excluding Connectors and Brackets) 376 x 530 x 276.22mm (Excluding Connectors and Brackets)
WEIGHT 17.6kg 19kg 19kg
TYPE OF COOLING Natural Cooling Natural Cooling Natural Cooling
WARRANTY 5 Years/10 Years

The warranty period depends on the final installation site of the Inverter. For more information please refer to warranty policy.

5 Years/10 Years

The warranty period depends on the final installation site of the Inverter. For more information please refer to warranty policy.

5 Years/10 Years

The warranty period depends on the final installation site of the Inverter. For more information please refer to warranty policy.

GRID REGULATION IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE2 17002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE2 17002, OVE-Richtlinie R25, G99, VDE-AR-N 4105 IEC 61727, IEC 62116, CEI 0-21, EN 50549, NRS 097, RD 140, UNE2 17002, OVE-Richtlinie R25, G99, VDE-AR-N 4105
SAFETY / EMC STANDARD IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2
POLLUTION DEGREE PD2 (Inside), PD3 (Outside) PD2 (Inside), PD3 (Outside) PD2 (Inside), PD3 (Outside)
MANUFACTURER COUNTRY China China China

Find out more about our products or becoming a supplier