Nexans Euromold 151SP Straight Plug (K151SP)

Product overview

Nexans Euromold 151SP Straight Plug

Nexans Euromold 151SP Straight Plug is a separable straight plug designed to connect polymeric insulated cable to cable. Mates with the elbow, straight and branch joint connectors.
Part Numbers: 151SP, K151SP.

Euromold 151SP is a separable straight plug specified to terminate and connect medium/high voltage cables in the following voltage classes:

  • 6/10 (12kV)
  • 6.35/11 (12kV)
  • 8.7/15 (17.5kV)
  • 12/20 (24kV)
  • 12.7/22 (24kV)

Technical Characteristics

  • The thick conductive EPDM jacket provides a total safe to touch screen, ensuring personnel safety.
  • Each straight plug is tested for AC withstand and partial discharge prior to leaving the factory.

Specification & Design

Euromold
Type 151SP
Voltage
Um
Current
Ir
Conductor Size
Min-Max
151SP 12 kV 200 Amps 16-95 mm2
K151SP 24 kV 200 Amps 16-95 mm2

 

Nexans Euromold 151SP DesignSeparable connector comprising:

  1. Conductive EPDM insert.
  2. Conductive EPDM jacket.
  3. Insulating EPDM layer moulded between the insert and the jacket.
  4. Type A interface as described by CENELEC EN 50180 and 50181.
  5. Conductor contact.

151SP Straight Plug Kit Contents

The complete (K)151SP straight plug kit comprises the following components. The kit also comprises silicon grease, wipers, installation instructions and crimp chart.

Nexans Euromold 151SP Kit

For Ordering Instructions and Part Number Selection Table of Nexans Euromold 151SP Straight Plugs (K151SP), please refer to the Technical Data Table Below. For additional General and Technical Information, download PDF File.

FREE Technical Advisory Service
E-Tech Components UK Ltd maintains a free technical advisory service.
Contact us for enquiries concerning this and all other products: +44 (0) 1744 762 929

Technical Data

ORDERING INSTRUCTIONS FOR 151SP

To order the straight plug, select the part number which gives the best centring to the cable core insulation diameter and substitute X using table X, according to your conductor size and type. Add a 'K' for use up to 24 kV.

Example: The copper wire screened cable is 12 kV, 50 mm2 stranded aluminium with a diameter over core insulation of 16,9 mm. Order a 151SP-A-50(K)M-12-2+11TL-FA/FAB straight plug kit.

PART NUMBER DIAMETER OVER CORE INSULATION MIN DIAMETER OVER CORE INSULATION MAX
151SP-A-X+11TL-FA/FAB 14.6 mm 18.7 mm
151SP-B-X+11TL-FB/FG 17.2 mm 21.2 mm
151SP-B-X+11TL-GA/GAB 19.7 mm 23 mm
151SP-C-X+11TL-GB/GH 22.2 mm 26.4 mm

 

TABLE X - ALUMINIUM & COPPER CONDUCTOR

CONDUCTOR SIZE  Alu Conductor
DIN Hexagonal
Alu Conductor
Deep Indent
Cu Conductor
DIN Hexagonal
16 mm2 - - 16(K)M-11-2
25 mm2 25(K)M-12-2 25KM-12-1 25(K)M-11-2
35 mm2 35(K)M-12-2 35KM-12-1 35(K)M-11-2
50 mm2 50(K)M-12-2 50(K)M-12-1 50(K)M-11-2
70 mm2 70(K)M-12-2 70(K)M-12-1 70(K)M-11-2
95 mm2 95(K)M-12-2 95(K)M-12-1 95(K)M-11-2

 