Prysmian BICON E1WF Cable Gland Kit - PCP Shroud (KA472 Series)

Product overview

Prysmian BICON E1WF Cable Gland Kit – PCP Shroud (KA472 Series) is a brass indoor and outdoor cable gland for use in hazardous locations. Suitable for use with all steel wire armoured cables.
Part Numbers: KA472-51, KA472-71, KA472-52, KA472-53, KA472-55, KA472-56, KA472-57, KA472-58, KA472-59, KA472-60, KA472-61, KA472-62, KA472-63, KA472-64.

Prysmian KA472 Features

  • Brass indoor and outdoor cable gland for use in hazardous areas.
  • Suitable for circular, galvanized steel wire armour cables with extruded polymeric bedding and oversheath.
  • Achieves IP66 seal onto cable and to enclosure with suitable sealing washer or thread sealant.
  • Three part armour lock provides mechanical cable retention and electrical continuity.
  • Inner PCP seal grips cable bedding and provides additional ingress protection.
  • Suitable for most climatic conditions – weatherproof and waterproof.
  • Standard and Nickel plated versions available.
  • Full installation instructions supplied.

Prysmian KA472 Technical Data

  • Certified II 2GD, Ex e II & Ex d IIC under ATEX directive 94/9/EC.
  • Atex Compliance Standards: EN 60079-0, EN 60079-1, EN 60079-7, EN 61241-0, EN 61241-1.
  • Certificate number Sira 02ATEX3092X.
  • IECEx Compliance Standards: IEC 60079-0, IEC 60079-1, IEC 60079-7, IEC 61241-0, IEC 61241-1.
  • Certificate number IECEx SIR 10.0071X
  • Service temperature range -60°C to +90°C.

Additional Information

May be used in:

  • Zones 0 , 1 & 2 with Ex ia IIA , B & C equipment.
  • Zones 1 & 2 with Ex ib IIA , B & C equipment.
  • Zones 1 & 2 with Ex e II equipment.
  • Zone 2 with Ex nA II equipment.
  • Zones 21 & 22 with Ex tD A21.

Where the cable is effectively filled, may also be used in:

  • Zones 1 & 2 with Ex d IIC equipment not containing a source of ignition & with a volume less than 2000 cm3.
  • Zones 1 & 2 with Ex d IIA & Ex d IIB equipment not containing a source of ignition & with any volume.
  • Zone 1 with Ex d IIA & Ex d IIB equipment containing a source of ignition & with a volume less than 2000 cm.
  • Zone 2 with Ex d IIA & Ex d IIB equipment containing a source of ignition & with any volume.
  • Zone 2 with Ex nR II equipment.

Kit Contents

  • E1WF Gland
  • Brass Earth Tag
  • Brass Locknut
  • Nylon Sealing Washer
  • PCP Shroud
  • (2 per kit up to and including 25mm size)

For more information on Prysmian BICON E1WF Cable Gland Kit – PCP Shroud (KA472 Series), please consult Datasheet below.

FREE Technical Advisory Service
E-Tech Components UK Ltd maintains a free technical advisory service.
Contact us for enquiries concerning this and all other products: +44 (0) 1744 762 929

Technical Data

Design Reference (Standard) Design Reference (Nickel Plated) Size (Metric) Qty per Kit Under Armour Min Ø (A) Under Armour Max Ø (A) Overall Ø (B) Min Overall Ø (B) Max Armour Wire Ø Entry Thread (D) Thread Length (E) Protrusion Length (F)  Hexagon A/F (G) Hexagon A/C (H)
KA472-51 KA472-51V 16 2 3.8 8.7 8.0 13.2 0.9 M16 x 1.5 15 41 23.4 26.7
KA472-71 KA472-71V 20SS 2 3.8 8.7 8.0 13.2 0.9 M20 x 1.5 15 41 23.4 26.7
KA472-52 KA472-52V 20S 2 8.0 11.8 8.0 15.8 0.9/1.25 M20 x 1.5 15 43 25.7 29.2
KA472-53 KA472-53V 20 2 11.8 14.2 11.7 20.8 0.9/1.25 M20 x 1.5 15 43 30.5 34.0
KA472-55 KA472-55V 25 2 14.0 20.1 17.0 27.2 1.25/1.6 M25 x 1.5 15 48 37.6 42.2
KA472-56 KA472-56V 32 1 19.7 26.6 23.5 33.5 1.6/2.0 M32 x 1.5 15 53 47.2 53.6
KA472-57 KA472-57V 40 1 26.6 32.4 29.0 39.9 1.6/2.0 M40 x 1.5 15 56 56.4 61.5
KA472-58 KA472-58V 50S 1 32.4 38.4 38.0 46.2 2.0/2.5 M50 x 1.5 15 61 60.0 66.0
KA472-59 KA472-59V 50 1 38.4 44.3 39.5 52.6 2.0/2.5 M50 x 1.5 15 61 70.1 77.2
KA472-60 KA472-60V 63S 1 44.3 50.3 50.0 58.9 2.5 M63 x 1.5 15 64 75.0 83.0
KA472-61 KA472-61V 63 1 50.3 56.2 51.3 65.3 2.5 M63 x 1.5 15 64 80.0 87.4
KA472-62 KA472-62V 75S 1 56.2 62.2 62.0 71.6 2.5 M75 x 1.5 15 73 90.2 99.1
KA472-63 KA472-63V 75 1 62.2 68.1 62.5 78.0 2.5 M75 x 1.5 15 73 98.8 109.2
KA472-64 KA472-64V 85 1 68.0 74.0 68.0 88.0  3.15 M85 x 2.0 20 102 115.1 126.0

Technical Information

  • Certified II 2GD, Ex e II & Ex d IIC under ATEX directive 94/9/EC.
  • Atex Compliance Standards: EN 60079-0, EN 60079-1, EN 60079-7, EN 61241-0, EN 61241-1.
  • Certificate number Sira 02ATEX3092X.
  • IECEx Compliance Standards: IEC 60079-0, IEC 60079-1, IEC 60079-7, IEC 61241-0, IEC 61241-1.
  • Certificate number IECEx SIR 10.0071X
  • Service temperature range -60°C to +90°C.
E1WF Ex d IIC - Ex e II Cable Gland Kit (PCP) KA472 Series technical

Kit Contents

  • E1WF Gland
  • Brass Earth Tag
  • Brass Locknut
  • Nylon Sealing Washer
  • PCP Shroud
  • (2 per kit up to and including 25mm size)

Additional Information

May be used in:

  • Zones 0 , 1 & 2 with Ex ia IIA , B & C equipment.
  • Zones 1 & 2 with Ex ib IIA , B & C equipment.
  • Zones 1 & 2 with Ex e II equipment.
  • Zone 2 with Ex nA II equipment.
  • Zones 21 & 22 with Ex tD A21.

Where the cable is effectively filled, may also be used in:

  • Zones 1 & 2 with Ex d IIC equipment not containing a source of ignition & with a volume less than 2000 cm3.
  • Zones 1 & 2 with Ex d IIA & Ex d IIB equipment not containing a source of ignition & with any volume.
  • Zone 1 with Ex d IIA & Ex d IIB equipment containing a source of ignition & with a volume less than 2000 cm.
  • Zone 2 with Ex d IIA & Ex d IIB equipment containing a source of ignition & with any volume.
  • Zone 2 with Ex nR II equipment.

 

 

Find out more about our products or becoming a supplier