CCG A2F VX VORTEx Barrier Compression Cable Gland (0412) is a Hazardous Area Glanding Device for Unfilled Unarmoured Cable. Suitable for indoor, outdoor, Group I, II, III, Zone 1, 2, 20, 21 and 22 hazardous areas.
CCG Part Numbers: 041200-16, 041200, 0412-0, 041201, 041222, 041202, 041233, 041203, 041244, 041204, 041255, 041205, 041266, 041206, 041277, 041207, 041208, 041299, 041209, 041210, 041211, 041212, 041213
Features & Benefits
- Passes the IECx, UKEX, and ATEX 100% pull test, so no additional cable clamping is required.
- For indoor, outdoor, Group I, II, III, Zone 1, 2, 20, 21 and 22 hazardous areas.
- Fitted with a specially formulated elastomeric displacement seal, giving superior cable retention, explosion protection, and IP rating.
- Precision manufactured from high-quality brass (Marine Grade Electroless Nickel Plated™) available in aluminium or stainless steel 316/316L on request. (Note: Aluminium is nit suitable for Group I applications).
- Supplied with a thread sealing gasket (parallel threads only).
CCG A2F VX Technical Data
Type: A2F VORTEx
Equipment Protection Levels: Ex db IIC, Ex eb IIC, Ex ta IIIC, Ex nR IIC
Gland Material: Brass (Marine Grade Electroless Nickel Plated™), Aluminium or Stainless Steel 316/316L
Seal Material: Standard Thermoset Elastomer or Extreme Temperature Seals
Sealing Gasket Material: HDPE, Nylon 66 or PTFE
Cable Type: Unarmoured
Sealing Area: Outer Sheath
Optional Accessories: Adaptor, Reducer, Earth Tag, Locknut, Serrated Washer and Shroud
Note: The installer should ensure that the materials are suitable for the installation environment.
Installation Standards
- IEC/BS EN
- IECEx
- ATEX
- UKEX
- Ingress Protection
- Deluge Protection
- Corrosion Protection
Hazardous Areas
A Hazardous Area is one in which there is potential for an explosion of gases, vapours, mists or dust or a combination of these. Such locations are petrochemical plants, offshore oil rigs, fuel filling stations, timber mills, coal mines, flour mills, paint spray booths, sewerage treatment plants, hospitals, explosive magazines and more.
Special precautions must be taken for the design, manufacture, installation and use of equipment and cable glands in such hazardous areas. Persons involved in selecting installing and maintaining electrical equipment for use in hazardous areas should be competently trained, have a full understanding of what a hazardous area is and have knowledge of the equipment protection levels and the installation standards involved.
Additional Technical Data on CCG A2F VX VORTEx Barrier Compression Cable Gland (0412) Part Numbers can be found on the table below. For Conforming Standards & Certificates as well as Fitting Instructions, please advise PDF File.
FREE Technical Advisory Service
E-Tech Components UK Ltd maintains a free technical advisory service.
Contact us for enquiries concerning this and all other products: +44 (0) 1744 762 929
Interested in this Product?
+44 (0)1744 762 929Technical Data
Product Code | Gland Size Ref. | Metric Entry Thread (C) | Metric Entry Thread (Min D) | NPT Entry Thread (C) | NPT Entry Thread (Min D) | Cable Detail (Min B) | Cable Detail (Max B) | Max Length (E) | Max Dia. Over Cores | Max No. of Cores | Hexagonal Detail (Max Flats) | Hexagonal Detail (Max Crns) | Installation Torque Value (Nm) |
041200-16 | 00-16ss | M16x1.5 | 15 | - | - | 3 | 8.5 | 25 | 8 | 6 | 24 | 27 | 32.5 |
041200 | 00-20ss | M20x1.5 | 15 | ½/¾ | 15 | 3 | 8.5 | 25 | 10.7 | 10 | 24 | 27 | 32.5 |
0412-0 | 0-20s | M20x1.5 | 15 | ½/¾ | 15 | 7 | 12 | 25 | 10.9 | 10 | 24 | 27 | 32.5 |
041201 | 1-20 | M20x1.5 | 15 | ½/¾ | 15 | 11 | 15 | 30 | 12.5 | 25 | 27 | 30 | 32.5 |
041222 | 2s-25s | M25x1.5 | 15 | ¾/1 | 15/19 | 11.5 | 17.5 | 30 | 16.5 | 48 | 35 | 39 | 47.5 |
041202 | 2-25 | M25x1.5 | 15 | ¾/1 | 15/19 | 15 | 20 | 30 | 16.5 | 48 | 35 | 39 | 47.5 |
041233 | 3s-32s | M32x1.5 | 15 | 1/1¼ | 19 | 16 | 22 | 30 | 24 | 76 | 42 | 47 | 55 |
041203 | 3-32 | M32x1.5 | 15 | 1/1¼ | 19 | 20 | 26.5 | 30 | 24 | 76 | 42 | 47 | 55 |
041244 | 4s-40s | M40x1.5 | 15 | 1¼/1½ | 19/21 | 22 | 31.5 | 38 | 32 | 96 | 52 | 59 | 65 |
041204 | 4-40 | M40x1.5 | 15 | 1¼/1½ | 19/21 | 26 | 34 | 38 | 32 | 96 | 52 | 59 | 65 |
041255 | 5s-50s | M50x1.5 | 15 | 1½/2 | 21 | 29 | 38 | 46 | 36.3 | 96 | 65 | 73 | 82.5 |
041205 | 5-50 | M50x1.5 | 15 | 1½/2 | 21 | 34 | 44.5 | 46 | 36.3 | 96 | 65 | 73 | 82.5 |
041266 | 6s-63s | M63x1.5 | 15 | 2/2½ | 21/30 | 38 | 50 | 52 | 47.9 | 100 | 80 | 90 | 97.5 |
041206 | 6-63 | M63x1.5 | 15 | 2/2½ | 21/30 | 44.5 | 56.5 | 52 | 47.9 | 100 | 80 | 90 | 97.5 |
041277 | 7s-75s | M75x1.5 | 15 | 2½/3 | 30/32 | 50 | 62 | 54 | 60 | 120 | 96 | 108 | 115.5 |
041207 | 7-75 | M75x1.5 | 15 | 2½/3 | 30/32 | 56 | 67.5 | 54 | 60 | 120 | 96 | 108 | 115.5 |
041208 | 8-80 | M80x2.0 | 20 | 3 | 32 | 59 | 69 | 68 | 61.5 | 140 | 96 | 108 | 120 |
041299 | 9s-90s | M90x2.0 | 20 | 3/3½ | 32/33 | 60 | 75 | 70 | 70.5 | 160 | 111 | 125 | 120 |
041209 | 9-90 | M90x2.0 | 20 | 3/3½ | 32/33 | 73 | 81.5 | 70 | 70.5 | 160 | 111 | 125 | 120 |
041210 | 10-100 | M100x2.0 | 20 | 3½/4 | 33/34 | 81 | 91 | 70 | 79 | 180 | 125 | 141 | 120 |
041211 | 11-115 | M115x2.0 | 20 | 4 | 34 | 91 | 101 | 70 | - | - | 135 | 152 | 175 |
041212 | 12-120 | M120x2.0 | 20 | - | - | 101 | 109 | 70 | - | - | 140 | 158 | 175 |
041213 | 13-130 | M130x2.0 | 20 | - | - | 109 | 116 | 70 | - | - | 146 | 164 | 175 |
All dimensions except NPT are in mm. Intermediate thread sizes are available on request. NPT threads should be tightened ‘wrench tight’. |