Prysmian BICON A2EXP NPT Dual Seal Cable Gland (495NE Series)

Product overview

Prysmian BICON A2EXP NPT Dual Seal Cable Gland (495NE Series) is a brass indoor and outdoor cable gland for use in hazardous locations. Suitable for use with circular unarmoured & braided cables.
Part Numbers: 495NE-03, 495NE-04, 495NE-05, 495NE-08, 495NE-10, 495NE-14, 495NE-15, 495NE-20, 495NE-21, 495NE-27, 495NE-32, 495NE-38, 495NE-44, 495NE-45.

Prysmian 495NE Features

  • Brass indoor and outdoor cable gland for use in hazardous areas.
  • Suitable for circular Unarmoured cables with extruded oversheath.
  • Fitted with silicone rubber low smoke, zero halogen seal.
  • Achieves IP66, IP68 (1 bar) and deluge proof (DTS01:1991) seal onto cable and to enclosure with suitable sealing washer or thread sealant.
  • Suitable for most climatic conditions – weatherproof, waterproof and deluge proof.
  • Standard and Nickel plated versions available.
  • Full installation instructions supplied.
  • *NPT Threaded glands are supplied as glands only.
  • **Other NPT sizes are available upon request.
  • Sizes 75s and 75 shall only be used for fixed installations.
  • In addition, the user or installer should ensure that they adequately clamp the cables.

Technical Data

  • Certified II 2GD, Ex e II & Ex d IIC under ATEX directive 94/9/EC.
  • Atex Compliance Standards: EN 60079-0, EN 60079-1, EN 60079-7, EN 61241-0, EN 61241-1.
  • Certificate number Sira99ATEX1086X.
  • IECEx Compliance Standards: IEC 60079-0, IEC 60079-1, IEC 60079-7, IEC 61241-0, IEC 61241-1.
  • Certificate number IECEx SIR 10.0069X
  • Service temperature range -50°C to +200°C.
  • UL Classified in accordance with IEC 60079-0, 60079-1 and 60079-7 for use in hazardous locations.
  • UL Listed for use in Class 1, Zone 0, 1 and 2 hazardous locations for Canada.

Additional Information

May be used in:

  • Zones 0 , 1 & 2 with Ex ia IIA , B & C equipment.
  • Zones 1 & 2 with Ex ib IIA , B & C equipment.
  • Zones 1 & 2 with Ex e II equipment.
  • Zones 1 & 2 with Ex p II equipment.
  • Zone 2 with Ex nA II equipment.
  • Zones 21 & 22 with Ex tD II equipment.

Where the cable is effectively filled, may also be used in:

  • Zones 1 & 2 with Ex d IIC equipment not containing a source of ignition & with a volume less than 2000 cm3.
  • Zones 1 & 2 with Ex d IIA & Ex d IIB equipment not containing a source of ignition & with any volume.
  • Zone 1 with Ex d IIA & Ex d IIB equipment containing a source of ignition & with a volume less than 2000 cm.
  • Zone 2 with Ex d IIA & Ex d IIB equipment containing a source of ignition & with any volume.
  • Zone 2 with Ex nR II equipment.

For more information on Prysmian BICON A2EXP NPT Dual Seal Cable Gland (495NE Series), please consult Datasheet below.

FREE Technical Advisory Service
E-Tech Components UK Ltd maintains a free technical advisory service.
Contact us for enquiries concerning this and all other products: +44 (0) 1744 762 929

Technical Data

Design Reference (Standard) Design Reference (Nickel Plated) Size Cable Diameter Ø (B) mm Min Cable Diameter Ø (B) mm Max Entry Thread (D) Thread Length (E) Protrusion Length (F) Hexagon A/F (G) Hexagon A/C (H)
495NE-03 495NE-03V ½"- 16 3.5 8.5 ½" NPT 15.5 65 25.7 28.7
495NE-04 495NE-04V ½"- 20S 8.0 11.5 ½" NPT 15.5 65 27.8 31.8
495NE-05 495NE-05V ½"- 20 8.0 16.0 ½" NPT 15.5 62 33 36.9
495NE-08 495NE-08V ¾"- 20 8.0 16.0 ¾" NPT 16.4 62 33 36.9
495NE-10 495NE-10V ¾"- 25 11.5 21.0 ¾" NPT 16.4 81 33 36.9
495NE-14 495NE-14V 1"- 25 11.5 21.0 1" NPT 19.5 81 37.5 42.2
495NE-15 495NE-15V 1"- 32 18.5 27.5 1" NPT 19.5 69 37.5 42.2
495NE-20 495NE-20V
1¼"-32
18.5 27.5 1¼" NPT 20.5 69 47.2 52.9
495NE-21 495NE-21V
1¼"-40
24.0 34.0 1¼" NPT 20.5 82 47.2 53.6
495NE-27 495NE-27V 1 ½"- 40 24.0 34.0 1 ½" NPT 21 82 56.4 63.1
495NE-32 495NE-32V 2"- 50 31.0 41.0 2" NPT 22 79 65 71.5
495NE-38 495NE-38V 2 ½"- 63 40.0 52.5 2 ½" NPT 32.5 113.5 80 87.4
495NE-44 495NE-44V 3"- 75S 52.5 58.0 3" NPT 33.5 78.5 98.8 109.2
495NE-45 495NE-45V 3"- 75 54.5 65.5 3" NPT 33.5 120 98.8 109.2

Technical Information

  • Certified II 2GD, Ex e II & Ex d IIC under ATEX directive 94/9/EC.
  • Atex Compliance Standards: EN 60079-0, EN 60079-1, EN 60079-7, EN 61241-0, EN 61241-1.
  • Certificate number Sira99ATEX1086X.
  • IECEx Compliance Standards: IEC 60079-0, IEC 60079-1, IEC 60079-7, IEC 61241-0, IEC 61241-1.
  • Certificate number IECEx SIR 10.0069X
  • Service temperature range -50°C to +200°C.
  • UL Classified in accordance with IEC 60079-0, 60079-1 and 60079-7 for use in hazardous locations.
  • UL Listed for use in Class 1, Zone 0, 1 and 2 hazardous locations for Canada.
A2EXP (NPT) Ex d IIC - Ex e II Dual Seal Cable Gland 495NE Series technical

Additional Information

May be used in:

  • Zones 0 , 1 & 2 with Ex ia IIA , B & C equipment.
  • Zones 1 & 2 with Ex ib IIA , B & C equipment.
  • Zones 1 & 2 with Ex e II equipment.
  • Zones 1 & 2 with Ex p II equipment.
  • Zone 2 with Ex nA II equipment.
  • Zones 21 & 22 with Ex tD II equipment.

Where the cable is effectively filled, may also be used in:

  • Zones 1 & 2 with Ex d IIC equipment not containing a source of ignition & with a volume less than 2000 cm3.
  • Zones 1 & 2 with Ex d IIA & Ex d IIB equipment not containing a source of ignition & with any volume.
  • Zone 1 with Ex d IIA & Ex d IIB equipment containing a source of ignition & with a volume less than 2000 cm.
  • Zone 2 with Ex d IIA & Ex d IIB equipment containing a source of ignition & with any volume.
  • Zone 2 with Ex nR II equipment.

 

 

Find out more about our products or becoming a supplier