The Sunsynk SunC2 Acure Hybrid Inverter (3.6kW | 5kW | 6kW | 7kW | 8kW) is a compact, all-in-one energy management solution integrating an inverter, solar charger and battery charger into a single unit. Designed for residential and small commercial solar systems, the SunC2 Acure Hybrid Inverter optimises energy use, provides uninterrupted power supply, and allows surplus solar energy to be stored for later use. Available in 3.6kW, 5kW, 6kW, 7kW and 8kW models, it delivers flexibility, efficiency and intuitive user control for modern energy-conscious homes and businesses.

Part Number Max. DC Input Power Max. Output Power
SunC2-3.6LV01(W/B) 3600W 7200W
SunC2-5.0LV01(W/B) 5000W 10000W
SunC2-6.0LV01(W/B) 6000W 12000W
SunC2-7.0LV01(W/B) 7000W 14000W
SunC2-8.0LV01(W/B) 8000W 16000W

Key Features & Benefits

  • Sunsynk Acure Hybrid InvertersColourful touch LCD display with interactive visual power flow and remote monitoring via Wi-Fi, Bluetooth and LAN
  • New user interface with built-in arc fault detection and solar panel theft protection for enhanced safety
  • Programmable smart switches, multi-stage MPPT charging, and configurable battery/grid priority for optimised energy use
  • Compatible with solar panels, grid power, generators, wind turbines, electric vehicles, and hot water tank control. Supports on-grid, off-grid, and UPS modes.
  • Built-in protections against overload, over-temperature, short-circuit, and theft. Smart battery charger protects battery health and extends lifespan.
  • LoRa-enabled connectivity for up to 10 Sunsynk Smartlynk devices and 2 CT coils. Supports parallel connection up to 16 units for larger installations.
  • Max charging/discharging currents: 90A (3.6kW), 120A (5kW), 135A (6kW), 175A (7kW), 190A (8kW). Supports 6 configurable time periods for optimised battery cycling.
  • Ideal for homes, offices, factories, remote/off-grid locations, construction sites, marine vessels, military locations, and telecom backup power
  • Two colour options available (black or white)

Why Choose Sunsynk SunC2 Acure Hybrid Inverters?

The SunC2 Hybrid Inverter is a next-generation energy management solution. Its all-in-one design allows seamless integration of solar generation, battery storage and grid power. Users can store surplus energy, reduce electricity costs and maintain continuous power during outages. Whether for residential, commercial or off-grid applications, the Sunsynk Inverter SunC2 delivers safety, flexibility and high performance in a compact, easy-to-install unit.


For Additional Information on Sunsynk SunC2 Acure Single-Phase Hybrid Inverters (3.6kW | 5kW | 6kW | 7kW | 8kW), please consult the Technical Data Table or PDF File below.

*Technical Data subject to change without notice.

FREE Technical Advisory Service
E-Tech Components UK Ltd maintains a free technical advisory service.
Contact us for enquiries concerning this and all other products: +44 (0) 1744 762 929

Technical Data

BATTERY INPUT DATA

SunC2-3.6LV01(W/B) SunC2-5.0LV01(W/B) SunC2-6.0LV01(W/B) SunC2-7.0LV01(W/B) SunC2-8.0LV01(W/B)
BATTERY TYPE Lead-acid or Lithium-ion Lead-acid or Lithium-ion Lead-acid or Lithium-ion Lead-acid or Lithium-ion Lead-acid or Lithium-ion
BATTERY VOLTAGE RANGE 40-60V 40-60V 40-60V 40-60V 40-60V
MAX CHARGING CURRENT 90A 120A 135A 175A 190A
MAX DISCHARGING CURRENT 90A 120A 135A 175A 190A
CHARGING STRATEGY FOR LI-ION BATTERY Self-adaption to BMS Self-adaption to BMS Self-adaption to BMS Self-adaption to BMS Self-adaption to BMS
NUMBER OF BATTERY INPUT 1 1 1 1 1

PV STRING INPUT DATA

SunC2-3.6LV01(W/B) SunC2-5.0LV01(W/B) SunC2-6.0LV01(W/B) SunC2-7.0LV01(W/B) SunC2-8.0LV01(W/B)
MAX. PV POWER ACCESS 7200W 10000W 12000W 14000W 16000W
MAX. PV INPUT POWER 5760W 8000W 9600W 11200W 12800W
MAX. PV INPUT VOLTAGE 500V 500V 500V 500V 500V
START-UP VOLTAGE 125V 125V 125V 125V 125V
MPPT VOLTAGE RANGE 150-425V 150-425V 150-425V 150-425V 150-425V
RATED PV INPUT VOLTAGE 370V 370V 370V 370V 370V
MAX. OPERATING PV INPUT CURRENT 18+18A 18+18A 18+18A 32+32A 32+32A
MAX. INPUT SHORT-CIRCUIT CURRENT 27+27A 27+27A 27+27A 48+48A 48+48A
NO. OF MPP TRACKERS / NO. OF STRINGS MPP TRACKER 2/1+1 2/1+1 2/1+1 2/2+2 2/2+2

AC INPUT / OUTPUT DATA

SunC2-3.6LV01(W/B) SunC2-5.0LV01(W/B) SunC2-6.0LV01(W/B) SunC2-7.0LV01(W/B) SunC2-8.0LV01(W/B)
RATED AC INPUT / OUTPUT ACTIVE POWER 3600W 5000W 6000W 7000W 8000W
MAX. AC INPUT / OUTPUT APPARENT POWER 3960VA 5500VA 6600VA 7700VA 8800VA
PEAK POWER (OFF-GRID) 2 times of rated power, 10s 2 times of rated power, 10s 2 times of rated power, 10s 2 times of rated power, 10s 2 times of rated power, 10s
RATED AC INPUT / OUTPUT CURRENT 16.4/15.7A 22.8/21.8A 27.3/26.1A 31.9/30.5A 36.4/34.8A
MAX. AC INPUT / OUTPUT CURRENT 18/17.3A 25/24A 30/28.7A 35/33.5A 40/38.3A
MAX. CONTINUOUS AC PASSTHROUGH (GRID TO LOAD) 35A 35A 40A 50A 50A
RATED INPUT / OUTPUT VOLTAGE / RANGE 220/230V 0.85Un-1.1Un 220/230V 0.85Un-1.1Un 220/230V 0.85Un-1.1Un 220/230V 0.85Un-1.1Un 220/230V 0.85Un-1.1Un
GRID CONNECTION FORM L+N+PE L+N+PE L+N+PE L+N+PE L+N+PE
RATED INPUT / OUTPUT GRID FREQUENCY / RANGE 50Hz/45-55Hz, 60Hz/55-65Hz 50Hz/45-55Hz, 60Hz/55-65Hz 50Hz/45-55Hz, 60Hz/55-65Hz 50Hz/45-55Hz, 60Hz/55-65Hz 50Hz/45-55Hz, 60Hz/55-65Hz
POWER FACTOR ADJUSTMENT RANGE 0.8 leading to 0.8 lagging 0.8 leading to 0.8 lagging 0.8 leading to 0.8 lagging 0.8 leading to 0.8 lagging 0.8 leading to 0.8 lagging
TOTAL CURRENT HARMONIC DISTORTION THDI <3% (of nominal power) <3% (of nominal power) <3% (of nominal power) <3% (of nominal power) <3% (of nominal power)
DC INJECTION CURRENT <0.5% In <0.5% In <0.5% In <0.5% In <0.5% In

EFFICIENCY

SunC2-3.6LV01(W/B) SunC2-5.0LV01(W/B) SunC2-6.0LV01(W/B) SunC2-7.0LV01(W/B) SunC2-8.0LV01(W/B)
MAX. EFFICIENCY 97.6% 97.6% 97.6% 97.6% 97.6%
EURO EFFICIENCY 96.5% 96.5% 96.5% 96.5% 96.5%
MPPT EFFICIENCY >99% >99% >99% >99% >99%

 

TECHNICAL SPECIFICATIONS - PROTECTION

SunC2-3.6LV01(W/B) SunC2-5.0LV01(W/B) SunC2-6.0LV01(W/B) SunC2-7.0LV01(W/B) SunC2-8.0LV01(W/B)
INTEGRATED DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Overvoltage Load Drop Protection, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (optional), Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch, DC Terminal Insulation Impedance Monitoring, Residual Current (RCD) Detection, Surge protection level DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Overvoltage Load Drop Protection, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (optional), Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch, DC Terminal Insulation Impedance Monitoring, Residual Current (RCD) Detection, Surge protection level DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Overvoltage Load Drop Protection, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (optional), Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch, DC Terminal Insulation Impedance Monitoring, Residual Current (RCD) Detection, Surge protection level DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Overvoltage Load Drop Protection, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (optional), Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch, DC Terminal Insulation Impedance Monitoring, Residual Current (RCD) Detection, Surge protection level DC Polarity Reverse Connection Protection, AC Output Overcurrent Protection, Thermal Protection, AC Output Overvoltage Protection, AC Output Short Circuit Protection, DC Component Monitoring, Overvoltage Load Drop Protection, Ground Fault Current Monitoring, Arc Fault Circuit Interrupter (optional), Power Network Monitoring, Island Protection Monitoring, Earth Fault Detection, DC Input Switch, DC Terminal Insulation Impedance Monitoring, Residual Current (RCD) Detection, Surge protection level
SURGE PROTECTION LEVEL TYPE II(DC), TYPE II(AC) TYPE II(DC), TYPE II(AC) TYPE II(DC), TYPE II(AC) TYPE II(DC), TYPE II(AC) TYPE II(DC), TYPE II(AC)

INTERFACE

SunC2-3.6LV01(W/B) SunC2-5.0LV01(W/B) SunC2-6.0LV01(W/B) SunC2-7.0LV01(W/B) SunC2-8.0LV01(W/B)
DISPLAY LCD+LED LCD+LED LCD+LED LCD+LED LCD+LED
COMMUNICATION INTERFACE RS485/RS232/CAN RS485/RS232/CAN RS485/RS232/CAN RS485/RS232/CAN RS485/RS232/CAN
MONITOR MODE GPRS/WIFI/Bluetooth/4G/LAN (optional) GPRS/WIFI/Bluetooth/4G/LAN (optional) GPRS/WIFI/Bluetooth/4G/LAN (optional) GPRS/WIFI/Bluetooth/4G/LAN (optional) GPRS/WIFI/Bluetooth/4G/LAN (optional)

GENERAL DATA

SunC2-3.6LV01(W/B) SunC2-5.0LV01(W/B) SunC2-6.0LV01(W/B) SunC2-7.0LV01(W/B) SunC2-8.0LV01(W/B)
OPERATING TEMPERATURE RANGE -40 to +60°C, >45°C Derating -40 to +60°C, >45°C Derating -40 to +60°C, >45°C Derating -40 to +60°C, >45°C Derating -40 to +60°C, >45°C Derating
PERMISSABLE AMBIENT HUMIDITY 0-100% 0-100% 0-100% 0-100% 0-100%
PERMISSABLE ALTITUDE 2000m 2000m 2000m 2000m 2000m
NOISE <30dB <30dB <30dB <30dB <30dB
INGRESS PROTECTION (IP) RATING IP65 IP65 IP65 IP65 IP65
INVERTER TOPOLOGY Non-Isolated Non-Isolated Non-Isolated Non-Isolated Non-Isolated
OVER VOLTAGE CATEGORY OVC II(DC), OVC III(AC) OVC II(DC), OVC III(AC) OVC II(DC), OVC III(AC) OVC II(DC), OVC III(AC) OVC II(DC), OVC III(AC)
CABINET SIZE (W x H x D) 366 x 630 x 281.41mm (Excluding Connectors and Brackets) 366 x 630 x 281.41mm (Excluding Connectors and Brackets) 366 x 630 x 281.41mm (Excluding Connectors and Brackets) 366 x 630 x 281.41mm (Excluding Connectors and Brackets) 366 x 630 x 281.41mm (Excluding Connectors and Brackets)
WEIGHT 27.1kg 27.1kg 27.1kg 27.1kg 27.1kg
TYPE OF COOLING Intelligent Air Cooling Intelligent Air Cooling Intelligent Air Cooling Intelligent Air Cooling Intelligent Air Cooling
WARRANTY 5 years (10 years when installed with a Sunsynk battery) 5 years (10 years when installed with a Sunsynk battery) 5 years (10 years when installed with a Sunsynk battery) 5 years (10 years when installed with a Sunsynk battery) 5 years (10 years when installed with a Sunsynk battery)
GRID REGULATION G98/G99, NRS 097-2-1, EN 50549-1 G98/G99, NRS 097-2-1, EN 50549-1 G98/G99, NRS 097-2-1, EN 50549-1 G98/G99, NRS 097-2-1, EN 50549-1 G98/G99, NRS 097-2-1, EN 50549-1
SAFETY / EMC STANDARD IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2 IEC/EN 61000-6-1/2/3/4, IEC/EN 62109-1, IEC/EN 62109-2