Elpress KRF Copper Cable Lugs - for Stranded & Flexible Cable (16-800mm²) - KRF16-6, KRF70-10, KRF95-10, KRF95-12

Product overview

Elpress KRF Copper Cable Lugs – for Stranded & Flexible Cable (16-800mm²) are produced from electrolytic copper and are tin plated. Suitable for both flexible and stranded Cu-Conductors, for sizes over 500mm² we recommend using KRF Terminals for flexible Cu-Conductors and KRD Terminals for stranded Cu-Conductors. Popular Part Numbers: KRF16-6, KRF70-10, KRF95-10, KRF95-12.

KRF240A-12: corresponding Siemens Wind Power (SWP) part number is A9B00046229.

KRF300A-12: corresponding Siemens Wind Power (SWP) part number is A9B00046231.

 

General Information

CU-CONNECTIONS
Elpress Cu-connections are produced from electrolytic 99.9% copper. Terminals and Through Connectors exist in a large variety of types for stranded as well as for flexible conductors. C-sleeves for earth conductor branch off also come in a large number of sized. If a standard type is not suitable, we produce tailor-made designs specific to the application.

  • KR/ KRF Terminals and KS/ KSF Connectors may be used for both stranded and flexible conductors.
  • KRD Terminals and KSD Connectors are used for stranded conductors.
  • KRT Terminals and KST Connectors equal the German “Standard types” (not DIN) and are used for stranded conductors.
  • C-Sleeves are used for branch-off or cross connections for mainly earth conductors such as for high lighting protection and earthing grids.

By Crimping Elpress Terminals & Connectors with Elpress Crimp Tools, connections are achieved that meet requirements of SEN 245010, BS 4579:1, VDE 0220:1, EN-IEC 61238:1 whichever is applicable.

MARKING
Elpress marking system for Cu-Connectors shows logotype, conductor area and ID-number for crimp die to be used. This system enables final inspection of proper die use as the die number is automatically imprinted by the die on the crimped barrel.

UL APPROVED
UL is an American standard which is also internationally accepted. Elpress standard Cu Terminals of types KR/ KS, KRF/ KSF. KRT/ KST are UL approved according to no. E205350. Cu Terminals of types KR/ KS, KRF/ KSF are for stranded and flexible copper wires, classes 2 and 5 according to IEC 60228, and have a working area of 1-500mm². Cu Terminals of types KRT/ KST is used for stranded copper wires 10-500mm².

DNV APPROVED
Elpress KRF/ KSF, KRT/ KST Terminals comply with DNV’s rules for the classification of ships and Det Norske Veritas’ Offshore Standrards. The Terminals are approved for installations on ships and mobile offshore units.

For more information on Elpress KRF Copper Cable Lugs – for Stranded & Flexible Cable (KRF16-6, KRF70-10, KRF95-10, KRF95-12), consult PDF File or Technical Data Table  below.

*Technical Data subject to change without notice.

 

FREE Technical Advisory Service
E-Tech Components UK Ltd maintains a free technical advisory service.
Contact us for enquiries concerning this and all other products: +44 (0) 1744 762 929

Technical Data

  • Data: electrolytic copper, tin plated.
  • Cable inspection hole, for stranded (class 2) and flexible (class 5) Cu conductors.
  • UL-approved (KRF 16-500mm²). DNV-approved (KRF 16-400mm²)
AWG Cat. No.

mm2 - bolt hole M

mm W d N N1 L Pcs / Pack Die No. Rec. Tool
6 KRF16-6 13 6 8 9 34 100 9 V600, V1300
6 KRF16-8 13 6 8 9 34 100 9 V600, V1300
6 KRF16-10 16 6 10 11 38 100 9 V600, V1300
6 KRF16-12 22 6 12 13 47 100 9 V600, V1300
4 KRF25-6 16 8 8 10 39 100 11 V600, V1300
4 KRF25-8 16 8 8 10 39 100 11 V600, V1300
4 KRF25-10 17 8 10 11 42 100 11 V600, V1300
2 KRF35-6 18 9 10 11 47 100 13 V600, V1300
2 KRF35-8 18 9 10 11 47 100 13 V600, V1300
2 KRF35-10 18 9 10 11 47 100 13 V600, V1300
2 KRF35-12 22 9 12 14 52 100 13 V600, V1300
1/0 KRF50-6 21 11 11 12 50 100 14,5 V600, V1300
1/0 KRF50-8 21 11 11 12 50 100 14,5 V600, V1300
1/0 KRF50-10 21 11 11 12 50 100 14,5 V600, V1300
1/0 KRF50-12 21 11 12 14 53 100 14,5 V600, V1300
1/0 KRF50-16 27 11 15 17 59 100 14,5 V600, V1300
2/0 KRF70-6 25 13 11 12 55 50 17 V600, V1300
2/0 KRF70-8 25 13 11 12 55 50 17 V600, V1300
2/0 KRF70-10 25 13 11 12 55 50 17 V600, V1300
2/0 KRF70-12 25 13 12 14 58 50 17 V600, V1300
2/0 KRF70-16 28 13 15 17 64 50 17 V600, V1300
4/0 KRF95-8 29 15 15 17 69 50 20 V600, V1300
4/0 KRF95-10 29 15 15 17 69 50 20 V600, V1300
4/0 KRF95-12 29 15 15 17 69 50 20 V600, V1300
4/0 KRF95-16 29 15 15 17 69 50 20 V600, V1300
250 KRF120-10 32 17 15 17 73 25 22 V1300, V250
250 KRF120-12 32 17 15 17 73 25 22 V1300, V250
250 KRF120-16 32 17 15 17 73 25 22 V1300, V250
300 KRF150-10 36 19 15 16 80 25 25 V1300, V250
300 KRF150-12 36 19 15 16 80 25 25 V1300, V250
300 KRF150-16 36 19 15 16 80 25 25 V1300, V250
300 KRF150-20 36 19 19 19 87 25 25 V1300, V250
350 KRF185-10 39 21 15 16 86 20 27 V1300, V250
350 KRF185-12 39 21 15 16 86 20 27 V1300, V250
350 KRF185-16 39 21 15 16 86 20 27 V1300, V250
350 KRF185-20 39 21 19 19 93 20 27 V1300, V250
500 KRF240A-10 42 22,5 19 20 96 10 30 V1300, V250
500 KRF240A-12 42 22,5 19 20 96 10 30 V1300, V250
500 KRF240A-16 42 22,5 19 20 96 10 30 V1300, V250
500 KRF240A-20 42 22,5 19 20 96 10 30 V1300, V250
600 KRF300A-10 46 24,5 15 19 93 10 32 V1300, V250
600 KRF300A-12 46 24,5 15 19 93 10 32 V1300, V250
600 KRF300A-16 46 24,5 20 20 99 10 32 V1300, V250
600 KRF300A-20 46 24,5 23 25 107 10 32 V1300, V250
600 KRF300A-24 46 24,5 23 25 107 10 32 V1300, V250
750 KRF400A-00 56 30 - - 118 10 38 V1300, V250
750 KRF400A-12 56 30 15 25 111 10 38 V1300, V250
750 KRF400A-16 56 30 20 20 111 10 38 V1300, V250
750 KRF400A-20 56 30 23 25 118 10 38 V1300, V250
750 KRF400A-24 56 30 23 25 118 10 38 V1300, V250
For Flexible Cu-conductors
1000 KRF500-00 61 33 70** 160 5 42 V250
1000 KRF500-16 61 33 25 35 150 5 42 V250
1000 KRF500-20 61 33 25 35 150 5 42 V250
1000 KRF500-24 61 33 25 35 150 5 42 V250
KRF630-00 75 39 80** 195 1 53 V250
KRF630-20 75 39 35 45 195 1 53 V250
KRF630-24 75 39 35 45 195 1 53 V250
KRF800-00 75 42 80** 195 1 53 V250
KRF800-24 75 42 35 45 195 1 53 V250
For Stranded Cu-conductors
KRD500-00 58 31 70** 160 5 40 V250
KRD500-16 58 31 25 35 150 5 40 V250
KRD500-20 58 31 25 35 150 5 40 V250
KRD500-24 58 31 25 35 150 5 40 V250
KRD630-00 65 34 75** 165 1 45 V250
KRD630-20 65 34 25 35 150 1 45 V250
KRD630-24 65 34 25 35 150 1 45 V250
KRD800-00 75 39 80** 195 1 53 V250
KRD800-24 75 39 35 45 195 1 53 V250
KRD1000-00 80 43 80** 195 1 56 V1470

Marking example KRF: 70 10F, KRD: 500 16 (Elpress logotype included)
70=mm² 10= palm hole for M10 F=type KRF, for stranded and flexible conductors
500=mm² 16= palm hole for M16
**total palm length