Nexans Euromold 400PB-10SA Surge Arrester
Product overview
Nexans Euromold 400PB-10SA Surge Arrester
Nexans Euromold 400PB-10SA Surge Arrester is designed to protect medium voltage components, including transformers, equipment, cable and accessories from high voltage surges resulting from lightning or switching. The 400PB-10SA surge arresters meet the test requirements of IEC 60099-4.
Euromold 400PB-10SA used for medium/high voltage cables in the following voltage classes:
- 6/10 (12kV)
- 6.35/11 (12kV)
- 8.7/15 (17.5kV)
- 12/20 (24kV)
- 12.7/22 (24kV)
- 18/30 (36kV)
- 19/33 (36kV)
- 20.8/36 (42kV)
Technical Characteristics
- This surge arrester is a metal oxide varistor surge arrester in an elbow configuration.
- Each arrester is tested for AC withstand, partial discharge and critical voltage prior to leaving the factory.
Specification & Design
The 400PB separable connector meets the requirements of CENELEC HD 629,1 S1.
Euromold Surge Arrester Type |
Nominal Discharge Current In |
Rated Voltage Ur |
Max Continuous Operating Voltage Uc |
Dim. L1-L2 (mm) |
400PB-10SA-6N | 10 kA | 6 kV | 4.8 kV | 270-310 |
400PB-10SA-9N | 10 kA | 9 kV | 7.2 kV | 270-310 |
400PB-10SA-12N | 10 kA | 12 kV | 9.6 kV | 270-310 |
400PB-10SA-15N | 10 kA | 15 kV | 12 kV | 270-310 |
400PB-10SA-18N | 10 kA | 18 kV | 14.4 kV | 270-310 |
400PB-10SA-22N | 10 kA | 22 kV | 17.6 kV | 270-310 |
400PB-10SA-24N | 10 kA | 24 kV | 19.2 kV | 370-410 |
400PB-10SA-27.5N | 10 kA | 27.5 kV | 22 kV | 370-410 |
400PB-10SA-30N | 10 kA | 30 kV | 24 kV | 370-410 |
400PB-10SA-33N | 10 kA | 33 kV | 26.4 kV | 370-410 |
400PB-10SA-36N | 10 kA | 36 kV | 28.8 kV | 370-410 |
400PB-10SA-40N | 10 kA | 40 kV | 32 kV | 470-510 |
400PB-10SA-42N | 10 kA | 42 kV | 33.6 kV | 470-510 |
400PB-10SA-45N | 10 kA | 45 kV | 36 kV | 470-510 |
400PB-10SA-51N | 10 kA | 51 kV | 40.8 kV | 470-510 |
- Conductive EPDM insert
- Conductive EPDM jacket
- Insulating EPDM layer moulded between the insert and the jacket
- Contact rod
- Earthing lead
- Earth connection
- Steel cap
- Metal oxide valve elements
- Type C interface as described by CENELEC EN 50180 and 50181.
For Ordering Instructions and Part Number Selection Table of Nexans Euromold 400PB-10SA Surge Arrester, please refer to the Technical Data Table Below. For additional General and Technical Information, download PDF File.
FREE Technical Advisory Service
E-Tech Components UK Ltd maintains a free technical advisory service.
Contact us for enquiries concerning this and all other products: +44 (0) 1744 762 929
Interested in this Product?
+44 (0)1744 762 929Technical Data
ORDERING INSTRUCTIONS FOR 400PB-10SATo order the surge arrester, specify the surge arrester type, as described on previous page. Example: For a maximum continuous operating voltage (r.m.s.) of 24 kV and a nominal discharge current of 10 kA. Order a 400PB-10SA-30N surge arrester.
|
Surge Arrester Type |
10 kA [1/20 μs] | 5 kA [8/20 μs] | 10 kA [8/20 μs] | 20 kA [8/20 μs] | 125 A [30/70 μs] | 500 A [30/70 μs] |
400PB-10SA-6N | 18.5 | 16.2 | 17.2 | 19.3 | 12.6 | 13.2 |
400PB-10SA-9N | 26.3 | 23 | 24.5 | 27.5 | 18.1 | 19.1 |
400PB-10SA-12N | 36.3 | 31.5 | 33.6 | 37.1 | 25.1 | 26.5 |
400PB-10SA-15N | 45.3 | 39.4 | 42 | 46.4 | 31.4 | 33.1 |
400PB-10SA-18N | 54.4 | 47.3 | 50.4 | 56.4 | 37.7 | 39.7 |
400PB-10SA-22N | 66.5 | 57.8 | 61.6 | 68.1 | 46 | 48.5 |
400PB-10SA-24N | 72.5 | 63 | 67.2 | 75.2 | 50.2 | 53 |
400PB-10SA-27.5N | 81.6 | 71 | 75.6 | 85 | 56.5 | 59.6 |
400PB-10SA-30N | 90.7 | 78.8 | 84 | 94 | 62.8 | 66.2 |
400PB-10SA-33N | 99.7 | 86.7 | 92.4 | 102.1 | 65 | 68.5 |
400PB-10SA-36N | 108.8 | 94.5 | 100.8 | 112.7 | 75.3 | 79.4 |
400PB-10SA-40N | 120.9 | 105.1 | 112 | 123.8 | 83.7 | 88.3 |
400PB-10SA-42N | 126.9 | 110.3 | 117.6 | 130 | 87.9 | 92.7 |
400PB-10SA-45N | 136 | 118.2 | 126 | 139.3 | 94.2 | 99.3 |
400PB-10SA-51N | 154.1 | 134 | 142.8 | 160.4 | 106.7 | 112.5 |