Prysmian BICON Barr-X Exd IIC Cable Gland (424TX Series)

Product overview

Prysmian BICON Barr-X Exd IIC Cable Gland (424TX Series) is a brass indoor and outdoor cable gland for use in Zone 1 and Zone 2 hazardous areas. Suitable for use with braid armoured cables.
Part Numbers: 424TX- 52, 424TX-53, 424TX-55, 424TX-56, 424TX-57, 424TX-59, 424TX-61, 424TX-63, 424TX-64, 424TX-02, 424TX-03, 424TX-05, 424TX-06, 424TX-07, 424TX-09, 424TX-11, 424TX-13, 424TX-14.

Prysmian 424TX Features

  • Brass indoor and outdoor cable gland for use in Zone 1 and Zone 2 hazardous areas.
  • Suitable for circular, wire braid armour cables with extruded polymeric oversheath and extruded or taped bedding.
  • Achieves IP66 seal onto cable and to enclosure with suitable sealing washer or thread sealant.
  • Provides mechanical cable retention and electrical continuity through the braid wire termination.
  • Suitable for most climatic conditions – weatherproof and waterproof.
  • Standard and Nickel plated versions available.
  • Full Installation Instructions supplied.
  • *Other NPT sizes available upon request.

Technical Data

  • Certified II 2GD, Ex e II & Ex d IIC under ATEX directive 94/9/EC.
  • Atex Compliance Standards: EN 60079-0, EN 60079-1, EN 60079-7, EN 61241-0, EN 61241-1.
  • Certificate number Sira04ATEX1080X.
  • IECEx Compliance Standards: IEC 60079-0, IEC 60079-1, IEC 60079-7, IEC 61241-0, IEC 61241-1.
  • Certificate number IECEx SIR 10.0072X
  • Service temperature range -60°C to +90°C.

Additional Information

May be used in:

  • Zones 0 , 1 & 2 with Ex ia IIA , B & C equipment.
  • Zones 1 & 2 with Ex ib IIA , B & C equipment.
  • Zones 1 & 2 with Ex ib IIA , B & C equipment with any volume.
  • Zones 1 & 2 with Ex e II equipment.
  • Zones 1 & 2 with Ex p II equipment.
  • Zone 2 with Ex nA II equipment.
  • Zone 2 with Ex nR II equipment.
  • Zones 21 & 22 with Ex tD A21.

For more information on Prysmian BICON Barr-X Exd IIC Cable Gland (424TX Series), please consult Datasheet below.

FREE Technical Advisory Service
E-Tech Components UK Ltd maintains a free technical advisory service.
Contact us for enquiries concerning this and all other products: +44 (0) 1744 762 929

Technical Data

Design Reference (Standard) Design Reference (Nickel Plated) Size (Metric) Size (NPT) Max. Dia. Over Conductors Max. No. Over Conductors Inner Sheath Min Ø Inner Sheath Max Ø Overall Ø (B) Min Overall Ø (B) Max Braid Armour Wire Ø Entry Thread (D) Thread Length (E) Protrusion Length (F)  Hexagon A/F (G) Hexagon A/C (H)
424TX- 52 424TX-52V 20S - 11.0 30 - 11.5 8.0 15.8 0.2/0.3 M20 x 1.5 15 67 30.5 34
424TX-53 424TX-53V 20 - 11.0 30 - 12.5 11.7 20.8 0.2/0.3 M20 x 1.5 15 64 30.5 34
424TX-55 424TX-55V 25 - 16.0 42 11.5 18.0 17.0 27.2 0.2/0.45 M25 x 1.5 15 65 37.6 42.2
424TX-56 424TX-56V 32 - 22.1 60 17.0 25.0 19.0 33.5 0.3/0.45 M32 x 1.5 15 77 47.3 53.6
424TX-57 424TX-57V 40 - 28.2 100 24.0 31.5 26.5 39.9 0.3/0.45 M40 x 1.5 15 77 56.4 61.5
424TX-59 424TX-59V 50 - 37.1 200 30.0 41.5 36.0 52.6 0.3/0.45 M50 x 1.5 15 84 70.1 77.2
424TX-61 424TX-61V 63 - 48.4 400 40.0 54.0 46.5 65.3 0.3/0.45 M63  x 1.5 15 90 80 87.4
424TX-63 424TX-63V 75 - 58.6 400 53.0 65.5 58.0 78.0 0.3/0.45 M75 x 1.5 15 96 98.8 109.2
424TX-64 424TX-64V 85 - 65.8 400 60.0 74.0 68.0 88.0 0.3/0.45 M85 x 2 20 108 115 126
424TX-02 424TX-02V - ½"-20S 11.0 30 - 11.5 8.0 15.8 0.2/0.3 ½" NPT 21.9 67 30.5 34
424TX-03 424TX-03V - ½"-20 11.0 30 - 12.5 11.7 20.8 0.2/0.3 ½" NPT 21.9 64 30.5 34
424TX-05 424TX-05V - ¾"-25 16.0 42 11.5 18.0 17.0 27.2 0.2/0.45 ¾" NPT 22.2 65 37.6 42.2
424TX-06 424TX-06V - 1"-32 22.1 60 17.0 25.0 19.0 33.5 0.3/0.45 1" NPT 27.5 77 47.3 53.6
424TX-07 424TX-07V - 1¼"-40 28.2 100 24.0 31.5 26.5 39.9 0.3/0.45 1¼" NPT 28.1 77 56.4 61.5
424TX-09 424TX-09V - 2"-50 37.1 200 30.0 41.5 36.0 52.6 0.3/0.45 2" NPT 29.4 84 70.1 77.2
424TX-11 424TX-11V - 2½"-63 48.4 400 40.0 54.0 46.5 65.3 0.3/0.45 2½" NPT 43.4 90 80 87.4
424TX-13 424TX-13V - 3"-75 58.6 400 53.0 65.5 58.0 78.0 0.3/0.45 3" NPT 45.0 96 98.8 109.2
424TX-14 424TX-14V - 3"-85 65.8 400 60.0 74.0 68.0 88.0 0.3/0.45 3" NPT 45.0 108 115 126

 

Technical Information

  • Certified II 2GD, Ex e II & Ex d IIC under ATEX directive 94/9/EC.
  • Atex Compliance Standards: EN 60079-0, EN 60079-1, EN 60079-7, EN 61241-0, EN 61241-1.
  • Certificate number Sira04ATEX1080X.
  • IECEx Compliance Standards: IEC 60079-0, IEC 60079-1, IEC 60079-7, IEC 61241-0, IEC 61241-1.
  • Certificate number IECEx SIR 10.0072X
  • Service temperature range -60°C to +90°C.
Barr-X Ex d IIC Cable Gland 424TX Series technical

Additional Information

May be used in:

  • Zones 0 , 1 & 2 with Ex ia IIA , B & C equipment.
  • Zones 1 & 2 with Ex ib IIA , B & C equipment.
  • Zones 1 & 2 with Ex ib IIA , B & C equipment with any volume.
  • Zones 1 & 2 with Ex e II equipment.
  • Zones 1 & 2 with Ex p II equipment.
  • Zone 2 with Ex nA II equipment.
  • Zone 2 with Ex nR II equipment.
  • Zones 21 & 22 with Ex tD A21.

 

 

Find out more about our products or becoming a supplier