Prysmian BICON Single Way Afumex Telcleat 385LSF Series (LSOH Polymer)
Product overview
Prysmian BICON Single Way Afumex Telcleat 385LSF Series (LSOH Polymer) is a single piece cleat which provides protection against all weather conditions and simple installation in a one piece, single fixing design. Authorised for use in London Underground.
Popular Part Nos: 385LSF01, 385LSF02, 385LSF03, 385LSF04, 385LSF05, 385LSF06, 385LSF07, 385LSF08.
Single Way Afumex Telcleats – Features & Benefits
- Prysmian BICON 385LSF Afumex Telcleat is suitable for use with cable diameters 10 to 51mm.
- Manufactured from LSOH polymer.
- Designed for use with Afumex LSOH and Saffire OHLS cables.
- Overlapping self-adjusting ranges.
- Sunlight (UV) and weather resistant.
- One piece, single fixing design.
- Can be double stacked on a single fixing.
- Operating temperature -40ºC to +40ºC.
- Tested in accordance with BS EN 50368.
- LUL APR Product ID 1259.
385LSF04, LUL approved telcleaτ
FREE Technical Advisory Service
E-Tech Components UK Ltd maintains a free technical advisory service.
Contact us for enquiries concerning this and all other products: +44 (0) 1744 762 929
Used in
London Underground
Interested in this Product?
+44 (0)1744 762 929Technical Data
Design Number | Cable Diameter A (mm) Min | Cable Diameter A (mm) Max | Standard Pack Quantities | Dimensions (mm) B Min | Dimensions (mm) B Max | Dimensions (mm) C Max | Dimensions (mm) D | Weight (g) | Roundhead Woodscrew masonry, concrete or wood ins X No | Screw Bolt for Cable Tray mm |
385LSF01 | 10.5 | 14.5 | 100 | 15 | 18 | 32 | 12 | 3.3 | 1 1/4 x 8 | M4 x 30 |
385LSF02 | 12.2 | 16.7 | 100 | 17 | 22 | 36 | 14 | 5.6 | 1 1/2 x 8 | M4 x 35 |
385LSF03 | 14.6 | 19.8 | 100 | 21 | 26 | 43 | 16 | 9.5 | 1 3/4 x 8 | M4 x 40 |
385LSF04 | 17.7 | 24.0 | 50 | 25 | 31 | 51 | 18 | 14.7 | 2 x 8 | M4 x 45 |
385LSF05 | 21.7 | 28.5 | 25 | 30 | 37 | 57 | 20 | 20.4 | 2 1/4 x 12 | M6 x 50 |
385LSF06 | 26.2 | 34.2 | 25 | 35 | 43 | 65 | 22 | 29.2 | 2 1/2 x 12 | M6 x 60 |
385LSF07 | 31.9 | 41.6 | 10 | 42 | 52 | 78 | 25 | 36.7 | 2 3/4 x 12 | M6 x 70 |
385LSF08 | 39.3 | 51.1 | 10 | 50 | 62 | 91 | 26 | 58.1 | 3 1/4 x 12 | M6 x 80 |
Performance Data
Test Standard | EN 50368:2003 |
Type | 6.12 Non-Metallic |
Impact Resistance | 6.2.4 Heavy -> 6.2.5 V.Heavy |
Lateral Load | 0.136 -> 0.781 kN |
Axial Load | 0.119 -> 1.024 kN |
Needle Flame | >120 secs |
Method Of Fixing
The single way cleat is opened up and placed around the cable so that the end of the cleat containing the slot will be in contact with the mounting surface, except for the 385LSF01, which should be reversed to put the slot uppermost. In this case an M5 washer should be used to prevent the nut entering the slot of the cleat.
*Technical information subject to change without notice