Prysmian BICON CFRZHMPJ Chemical & Fire Resistance Cable Joints (LV)
Product overview
Prysmian BICON CFRZHMPJ
Prysmian BICON CFRZHMPJ Chemical & Fire Resistance Cable Jointing Kits are Immersion & Zero Halogen Straight Joints for NEK 606 BFOU Fire Resistant Power & Control Cables: Single & Multi Core 1.5mm² to 300mm².
Part Numbers: CFRZHMPJ3, CFRZHMPJ4, CFRZHMPJ5, CFRZHMPJ6, CFRZHMPJ7.
Features & Benefits
- Rated voltage 1000V
- Tested and approved to:
=> BS EN 50393:2015 – Test methods and requirements for accessories for use on distribution cables of rated voltage 0,6/1,0 (1,2) kV - IEC 60331-1 (90mins Fire & Vibration + 15 Mins Immersion)
- BS 6387:2013 – Test method for resistance to fire of cables required to maintain circuit integrity under fire conditions (categories C, W & Z).
- IEC 61034-2:2005+A1:2013 – Measurement of smoke density of cables burning under defined conditions.
- BS 6899—oil resistance
- Low Hazard Isocyanate free JEM resin.
- Twin pack mixing in clear laminate sachets.
- Extremely low viscosity resin with enhanced adhesion.
- Rigid glass reinforced phenolic joint shells which are Chemical resisting, Fire retardant and LSOH.
- Slim-line design for use with compression connectors.
- Requires compression connectors which come separately.
CFRZHMPJ Technical Information
- Low Voltage Straight Joints for 600/1000 Volt NEK 606 BFOU fire Performance cables.
- Tested and approved to BS EN 50393 : 2015
- Fire tests on complete joints to:
=> IEC 60331-1 (90mins + 15 mins immersion)
=> BS 6387 categories C, W & Z
General Technical Data
In this range a Phenolic resin shell is used to provide excellent resistance to Hydrocarbons found in Oil, Gas and Petrochemical installations. Tests to demonstrate the chemical resistance of both the shell and the sealing putty have been carried out to BS6899 using ASTM oils, numbers 2 and 3. This calls for 24 hour immersion at 100°C and specifies permissible changes in mechanical properties before and after ageing. In each case minimal changes were observed after immersion in both oils, under conditions where most conventional polymers used in cable construction would not survive.
Download PDF file for more information on Prysmian BICON CFRZHMPJ Chemical & Fire Resistance & Immersion & Zero Halogen Cable Jointing Kits.
*Technical Data subject to change without notice.
FREE Technical Advisory Service
E-Tech Components UK Ltd maintains a free technical advisory service.
Contact us for enquiries concerning this and all other products: +44 (0) 1744 762 929
Interested in this Product?
+44 (0)1744 762 929Technical Data
SHELL DIMENSIONS |
PART NUMBER | A (mm) | B (mm) | C (mm) |
CFRZHMPJ3 | 405 | 100 | 80 |
CFRZHMPJ4 | 430 | 110 | 90 |
CFRZHMPJ5 | 560 | 160 | 130 |
CFRZHMPJ6 | 740 | 180 | 145 |
CFRZHMPJ7 | 870 | 190 | 145 |
JOINT SELECTION |
Conductor | Single Core | Two Core | Three Core | Four Core | Connector Required |
1.5 mm2 | CFRZHMPJ-3 | CFRZHMPJ-3 | CFRZHMPJ-3 | CFRZHMPJ-3 | BT2CS |
2.5 mm2 | CFRZHMPJ-3 | CFRZHMPJ-3 | CFRZHMPJ-3 | CFRZHMPJ-3 | BT2CS |
4 mm2 | CFRZHMPJ-3 | CFRZHMPJ-4 | CFRZHMPJ-4 | CFRZHMPJ-4 | BT6CS |
6 mm2 | CFRZHMPJ-3 | CFRZHMPJ-4 | CFRZHMPJ-4 | CFRZHMPJ-4 | BT6CS |
10 mm2 | CFRZHMPJ-3 | CFRZHMPJ-4 | CFRZHMPJ-4 | CFRZHMPJ-4 | BT10CS |
16 mm2 | CFRZHMPJ-3 | CFRZHMPJ-4 | CFRZHMPJ-4 | CFRZHMPJ-4 | BT16CS |
25 mm2 | CFRZHMPJ-3 | CFRZHMPJ-4 | CFRZHMPJ-4 | CFRZHMPJ-4 | BT25CS |
35 mm2 | CFRZHMPJ-3 | CFRZHMPJ-4 | CFRZHMPJ-4 | CFRZHMPJ-5 | BT35CS |
50 mm2 | CFRZHMPJ-4 | CFRZHMPJ-4 | CFRZHMPJ-5 | CFRZHMPJ-5 | BT50CS |
70 mm2 | CFRZHMPJ-4 | CFRZHMPJ-5 | CFRZHMPJ-5 | CFRZHMPJ-5 | BT70CS |
95 mm2 | CFRZHMPJ-4 | CFRZHMPJ-5 | CFRZHMPJ-5 | CFRZHMPJ-5 | BT95CS |
120 mm2 | CFRZHMPJ-4 | CFRZHMPJ-5 | CFRZHMPJ-6 | CFRZHMPJ-6 | BT120CS |
150 mm2 | CFRZHMPJ-5 | CFRZHMPJ-5 | CFRZHMPJ-6 | CFRZHMPJ-6 | BT150CS |
185 mm2 | CFRZHMPJ-5 | CFRZHMPJ-6 | CFRZHMPJ-6 | CFRZHMPJ-6 | BT185CS |
240 mm2 | CFRZHMPJ-5 | CFRZHMPJ-6 | CFRZHMPJ-7 | CFRZHMPJ-7 | BT240CS |
300 mm2 | CFRZHMPJ-5 | CFRZHMPJ-6 | CFRZHMPJ-7 | CFRZHMPJ-7 | BT300CS |